SIPLUS extreme 產(chǎn)品是基于西門子工業(yè)標(biāo)準(zhǔn)產(chǎn)品的。此處列出的內(nèi)容來(lái)自相關(guān)的標(biāo)準(zhǔn)產(chǎn)品。添加了特定 SIPLUS extreme 信息
SB 1223 數(shù)字量輸入/輸出信號(hào)模塊允許:
信號(hào)板直接插到每個(gè) S7-1200 CPU 前面的插座中。
SB 1223 數(shù)字量輸入/輸出信號(hào)板
Order number |
6AG1223-0BD30-4XB0 |
6AG1223-0BD30-5XB0 |
6AG1223-3AD30-5XB0 |
6AG1223-3BD30-5XB0 |
|
---|---|---|---|---|---|
|
SIPLUS S7-1200 SB1223 2DI / 2DO |
SIPLUS S7-1200 SB1223 2DI/2DO |
SIPLUS S7-1200 SB1223 2DI/2DQ, 5VDC |
SIPLUS S7-1200 SB1223 2DI/2DQ, 24VDC |
|
Product type designation |
|
|
|
|
|
Supply voltage |
|
|
|
|
|
permissible range, lower limit (DC) |
20.4 V |
20.4 V |
|
|
|
permissible range, upper limit (DC) |
30 V |
30 V |
|
|
|
Input current |
|
|
|
|
|
from backplane bus 5 V DC, typ. |
50 mA |
50 mA |
50 mA |
50 mA |
|
Output voltage |
|
|
|
|
|
Power supply to the transmitters |
|
|
|
|
|
|
4 mA; per channel |
4 mA; per channel |
4 mA; per channel |
4 mA; per channel |
|
Power loss |
|
|
|
|
|
Power loss, typ. |
1 W |
1 W |
1 W |
1 W |
|
Digital inputs |
|
|
|
|
|
Number of digital inputs |
2; Current-sinking |
2; Current-sinking |
2; Current-sourcing |
2; Current-sourcing |
|
|
1 |
1 |
1 |
1 |
|
Input characteristic curve in accordance with IEC 61131, type 1 |
Yes |
Yes |
Yes |
Yes |
|
Number of simultaneously controllable inputs |
|
|
|
|
|
all mounting positions |
|
|
|
|
|
|
2 |
2 |
2 |
2 |
|
Input voltage |
|
|
|
|
|
|
DC |
DC |
|
|
|
|
24 V |
24 V |
5 V |
24 V |
|
|
0 to 5 V |
0 to 5 V |
0 to 1 V |
0 to 5 V |
|
|
+15 to +30V |
+15 to +30V |
2 to 6 V |
+15 to +30V |
|
Input current |
|
|
|
|
|
|
1 mA |
1 mA |
3 mA |
2 mA |
|
|
|
|
6 mA |
5.8 mA |
|
|
0.5 A |
0.5 A |
|
14 mA |
|
Input delay (for rated &#118alue of input voltage) |
|
|
|
|
|
for standard inputs |
|
|
|
|
|
|
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
|
|
2 μs |
2 μs |
2 μs |
2.5 μs |
|
|
10 μs |
10 μs |
|
|
|
for interrupt inputs |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
for counter/technological functions |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
Cable length |
|
|
|
|
|
|
500 m |
500 m |
50 m |
Standard input: 500 m, high-speed counters: 50 m |
|
|
300 m |
300 m |
|
|
|
Digital outputs |
|
|
|
|
|
Number of digital outputs |
2; MOSFET, solid-state (current-sinking/current-sourcing) |
2; MOSFET, solid-state (current-sinking/current-sourcing) |
2; MOSFET, solid-state (current-sinking/current-sourcing) |
2; MOSFET, solid-state (current-sinking/current-sourcing) |
|
|
1 |
1 |
1 |
1 |
|
short-circuit protection |
No |
No |
No |
No |
|
Switching capacity of the outputs |
|
|
|
|
|
|
0.5 A |
0.5 A |
0.1 A |
0.1 A |
|
|
5 W |
5 W |
|
|
|
Load resistance range |
|
|
|
|
|
|
0.6 Ω |
0.6 Ω |
5 Ω |
10 Ω |
|
Output voltage |
|
|
|
|
|
|
24 V |
24 V |
5 V |
24 V |
|
|
0.1 V; with 10 kOhm load |
0.1 V; with 10 kOhm load |
0.4 V |
0.1 V; with 10 kOhm load |
|
|
|
|
6 V |
|
|
Output current |
|
|
|
|
|
|
0.5 A |
0.5 A |
0.1 A |
0.1 A |
|
|
|
|
0.11 A |
|
|
|
10 μA |
10 μA |
|
10 μA |
|
Cable length |
|
|
|
|
|
|
500 m |
500 m |
50 m |
50 m |
|
|
150 m |
150 m |
|
|
|
Interrupts/diagnostics/status information |
|
|
|
|
|
Alarms |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
Diagnostic messages |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
Diagnostics indication LED |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
|
Yes |
Yes |
Yes |
Yes |
|
Degree and class of protection |
|
|
|
|
|
Degree of protection acc. to EN 60529 |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
Standards, approvals, certificates |
|
|
|
|
|
CE mark |
Yes |
Yes |
|
|
|
Ambient conditions |
|
|
|
|
|
Free fall |
|
|
|
|
|
|
0.3 m; five times, in dispatch package |
0.3 m; five times, in dispatch package |
0.3 m; five times, in dispatch package |
0.3 m; five times, in dispatch package |
|
Ambient temperature during operation |
|
|
|
|
|
|
0 °C; = Tmin |
-25 °C; = Tmin |
-25 °C; = Tmin |
-25 °C; = Tmin |
|
|
55 °C; = Tmax |
55 °C; = Tmax |
55 °C; = Tmax |
55 °C; = Tmax |
|
Ambient temperature during storage/transportation |
|
|
|
|
|
|
-40 °C |
-40 °C |
-40 °C |
-40 °C |
|
|
70 °C |
70 °C |
70 °C |
70 °C |
|
Extended ambient conditions |
|
|
|
|
|
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
|
Relative humidity |
|
|
|
|
|
|
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) |
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) |
100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
|
Resistance |
|
|
|
|
|
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
|
|
Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
|
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
|
Mechanics/material |
|
|
|
|
|
Type of housing (front) |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
Dimensions |
|
|
|
|
|
Width |
38 mm |
38 mm |
38 mm |
38 mm |
|
Height |
62 mm |
62 mm |
62 mm |
62 mm |
|
Depth |
21 mm |
21 mm |
21 mm |
21 mm |
|
Weights |
|
|
|
|
|
Weight, approx. |
40 g |
40 g |
40 g |
40 g |