ES0Z1B06ACS0 S7706基本引擎交流組合配置(含一體化非PoE總裝機(jī)箱,SRUA主控板*2,800W交流電源*2)
LE0W01DPDB 直流配電盒組件(共4路40A輸出,單路1600W,含電源線)
新聞:蚌埠ES0Z1B06ACS0多少錢
IN6W18L10A 交流分線盒組件(共8路10A輸出,單路1600W,含電源線)
IM1W24APD 交流分線盒組件(共4路16A輸出,單路2500W,含電源線)
EH1M00PDBS01 直流配電盒組件(共8路60A輸出,單路2200W,含電源線)
EH1FP01 框式交換機(jī)假拉手條
ES0DG48CEAT0 36端口十兆/百兆/千兆以太網(wǎng)電接口和12端口百兆/千兆以太網(wǎng)光接口板(EA,RJ45/SFP)
ES0D0X4UXC00 4端口萬兆以太網(wǎng)光接口板(EC,XFP)
ES0D0S24XA00 24端口百兆/千兆以太網(wǎng)光接口和2端口萬兆以太網(wǎng)光接口板(EA,SFP/XFP)
ES0D0G48VA00 48端口十兆/百兆/千兆以太網(wǎng)POE電接口板(EA,RJ45,POE)
ES0D0X4UXA00 4端口萬兆以太網(wǎng)光接口板(EA,XFP)
新聞:蚌埠ES0Z1B06ACS0多少錢
ES0D0G24CA00 24端口百兆/千兆以太網(wǎng)光接口和8端口十兆/百兆/千兆Combo電接口板(SA,SFP/RJ45)
ES0D0X2UXC00 2端口萬兆以太網(wǎng)光接口板(EC,XFP)
ES0D0T24XA00 24端口十兆/百兆/千兆以太網(wǎng)電接口和2端口萬兆以太網(wǎng)光接口板(EA,RJ45/XFP)
ES0D0X2UXA00 2端口萬兆以太網(wǎng)光接口板(EA,XFP)
ES0D0F48TA00 48端口十兆/百兆以太網(wǎng)電接口板(EA,RJ45)
ES0D0G48SA00 48端口百兆/千兆以太網(wǎng)光接口板(EA,SFP)
ES0D0G48SC00 48端口百兆/千兆以太網(wǎng)光接口板(EC,SFP)
ES0D0G48TC00 48端口十兆/百兆/千兆以太網(wǎng)電接口板(EC,RJ45)
ES0D0G48TA00 48端口十兆/百兆/千兆以太網(wǎng)電接口板(EA,RJ45)
ES0D0G24SC00 24端口百兆/千兆以太網(wǎng)光接口板(EC,SFP)
ES0D0G24SA00 24端口百兆/千兆以太網(wǎng)光接口板(SA,SFP)
ES0D00FSUA00 增強(qiáng)靈活業(yè)務(wù)子卡
新聞:蚌埠ES0Z1B06ACS0多少錢
ES0D00SRUB00 S7706/S7712主控處理單元B(可選配時(shí)鐘)
ES0D00SRUA00 S7706/S7712主控處理單元A
ES0D0F48TC00 48端口十兆/百兆以太網(wǎng)電接口板(EC,RJ45)
ES0DG48TFA00 48端口十兆/百兆/千兆以太網(wǎng)電接口板(FA,RJ45)
ES0D0X12SA00 12端口萬兆以太網(wǎng)光接口板(SA,SFP+)
ES0DG24TFA00 24端口十兆/百兆/千兆以太網(wǎng)電接口板(FA,RJ45)
EH1D200CMU00 集中監(jiān)控板
ES1D2L02QFC0 2端口40GE以太網(wǎng)光接口板(FC,QSFP+)
ES1D2X04XED0 4端口萬兆以太網(wǎng)光接口板(ED,XFP)
ES1D2G48SFA0 48端口百兆/千兆以太網(wǎng)光接口板(FA,SFP)
ES1D2G48SED0 48端口百兆/千兆以太網(wǎng)光接口板(ED,SFP)
ES1D2X16SFC0 16端口萬兆以太網(wǎng)光接口板(FC,SFP+)
ES1D2X40SFC0 40端口萬兆以太網(wǎng)光接口板(FC,SFP+)
ES1D2X08SED4 8端口萬兆以太網(wǎng)光接口板(ED,SFP+)
ES02VSTSA 集群業(yè)務(wù)子卡
新聞:蚌埠ES0Z1B06ACS0多少錢
ES1D2G24SED0 24端口百兆/千兆以太網(wǎng)光接口板(ED,SFP)
ES1D2G48TED0 48端口十兆/百兆/千兆以太網(wǎng)電接口板(ED,RJ45)
ES1D2G48SBC0 48端口百兆/千兆以太網(wǎng)光接口板(BC,SFP)
ES1D2G48TBC0 48端口十兆/百兆/千兆以太網(wǎng)電接口板(BC,RJ45)
ES1D2S24XEC0 24端口百兆/千兆以太網(wǎng)光接口和2端口萬兆以太網(wǎng)光接口板(EC,SFP/XFP)
ES1D2S08SX1E 8端口萬兆光接口和8端口百兆/千兆光接口和8端口十兆/百兆/千兆combo電接口板(X1E,RJ45/SFP/SFP+)
ES1D2G48TX1E 48端口十兆/百兆/千兆以太網(wǎng)電接口板(X1E,RJ45)
ES1D2S04SX1E 4端口萬兆光接口和24端口百兆/千兆光接口和8端口十兆/百兆/千兆combo電接口板(X1E,RJ45/SFP/SFP+)
ES1D2G48SX1E 48端口百兆/千兆以太網(wǎng)光接口板(X1E,SFP)
ACU2 WLAN ACU2 無線接入控制板(含128 AP控制資源)
ET1D2IPS0S00 入侵防御和入侵檢測(cè)業(yè)務(wù)處理板A-含華為通用安全平臺(tái)軟件
ET1D2FW00S00 下一代防火墻業(yè)務(wù)處理板A-含華為通用安全平臺(tái)軟件
ET1D2FW00S01 下一代防火墻業(yè)務(wù)處理板B-含華為通用安全平臺(tái)軟件
新聞:蚌埠ES0Z1B06ACS0多少錢
嚴(yán)禁帶病和酒后進(jìn)行試驗(yàn)。被試物須無機(jī)械損傷,與試驗(yàn)物周圍帶電體應(yīng)有足夠安全間距,被試物應(yīng)可靠接地。穿戴好防護(hù)用品。試驗(yàn)電工工作中要求。試驗(yàn)時(shí)不少于二人,應(yīng)一名有經(jīng)驗(yàn)者為試驗(yàn)負(fù)責(zé)人。高壓試驗(yàn)人員應(yīng)明確分工,試驗(yàn)時(shí)應(yīng)裝遮欄,或在被試區(qū)專人警戒。試驗(yàn)負(fù)責(zé)人在現(xiàn)場(chǎng)發(fā)令,其他人應(yīng)服從指揮。當(dāng)發(fā)現(xiàn)人員,設(shè)備危險(xiǎn)時(shí),有權(quán)停止試驗(yàn)。試驗(yàn)中,試驗(yàn)人員不準(zhǔn)擅離崗位。特殊情況要離開時(shí),應(yīng)停止試驗(yàn),拆除試驗(yàn)電源。重新試驗(yàn)要檢查結(jié)線無變動(dòng)后,方可接上電源。