夜色网,色欲aⅴ精品一区二区三区四区,国产精品jizz视频国产y网,欧美精品综合视频一区二区

產(chǎn)品簡(jiǎn)介
G120變頻器6SL3210-1PE33-7CL0西門子
G120變頻器6SL3210-1PE33-7CL0西門子
產(chǎn)品價(jià)格:¥43200
上架日期:2022-08-19 15:30:03
產(chǎn)地:江蘇南京市
發(fā)貨地:上海松江區(qū)
供應(yīng)數(shù)量:不限
最少起訂:1臺(tái)
瀏覽量:198
資料下載:暫無(wú)資料下載
其他下載:暫無(wú)相關(guān)下載
詳細(xì)說明
    商品描述
    價(jià)格說明
    聯(lián)系我們;15900773813
    品牌
    西門子
    是否進(jìn)口
    加工定制
    產(chǎn)品認(rèn)證
    CE
    系列
    G120
    物料編碼
    1
    產(chǎn)地
    德國(guó)
    商品代碼
    85044084
    包裝尺寸
    67.00 x 210.00 x 237.00
    可售賣地
    全國(guó)
    型號(hào)
    6SL3210-1PE33-7CL0
    西門子 G120變頻器6SL3210-1PE33-7CL0功能及參數(shù)                                                 

    概述

    PM240?2 Power Modules – 0.55 kW to 250 kW (0.75 hp to 400 hp), IP20 degree of protection

    PM240?2 Power Modules, frame sizes FSA to FSG (with Control Unit and Operator Panel)

    The PM240?2 Power Modules are based on a new hardware platb. This permits an increase in power density as well as the application of innovative cooling concepts (push-through technology) with especially high requirements in terms of control cabinet cooling.

    Furthermore, the PM240-2 Power Module is also suitable for use in safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transbed into a Safety Integrated Drive (see section Control Units).

    The PM240?2 Power Modules in frame sizes FSA to FSF are available both with and without an integrated line filter class A of compact design for 200 V, 400 V and 690 V line voltages (except PM240?2 frame sizes FSD to FSF: 200 V). The PM240?2 Power Modules in frame size FSG are available with an integrated line filter Category C3 of compact design for 400 V and 690 V line voltages, also with integrated line filter Category C2 for a line voltage of 400 V. In addition, a DC b reactor is integrated in the PM240?2 Power Modules, frame sizes FSD to FSG, and therefore no line reactor is required.

    The PM240-2 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded TN/TT systems and non-grounded IT systems.

    The PM240?2 Power Module has an integrated braking chopper. In generating mode, the excess energy of the DC b can be dissipated by means of an optional braking resistor.

    The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

    Push-through variant

    Example: PM240?2 Power Modules, degree of protection IP20, push-through variant, frame sizes FSD to FSF (with Control Unit and Operator Panel)

    The push-through variants in the frame sizes FSA to FSF allow the cooling fins of the Power Modules to be pushed through the rear panel of the control cabinet. Push-through variants should be used in applications where the amount of power loss generated inside the control cabinet itself must be minimized.

    Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.For more inbation, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.

    PM250 Power Modules – 7.5 kW to 90 kW (10 hp to 125 hp), IP20 degree of protection

    PM250 Power Modules, frame sizes FSC to FSF

    PM250 Power Modules are suitable for a large number of applications in general mechanical engineering. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking chopper is not required).

    The PM250 Power Module features an absoluby unique technology – Efficient Infeed Technology. This feature provides the ability to feed energy back into the supply system in the generator mode (electronic braking) so that the energy is not converted into heat in a braking resistor. This saves space in the control cabinet. The time-consuming process of dimensioning the braking resistor and the expense of the extra wiring are eliminated. Furthermore, heat losses in the control cabinet are reduced.

    Further, the innovative circuit design reduces the line harmonics. There is no need to use an optional line reactor at the supply infeed. This saves space and costs for engineering and procurement.

    The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

    Frame sizes FSD to FSF of the PM250 Power Modules are available both with as well as without integrated line filter class A.

    For frame size FSC of the PM250 Power Module with an integrated line filter class A, an additional base filter of class B is available for achieving class B (see section Line-side components).

    The PM250 Power Module is also designed for safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transbed into a Safety Integrated Drive (see section Control Units).

    The PM250 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded TN/TT systems and non-grounded IT systems.

    Note:

    Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.For more inbation, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.

    集成

    All Power Modules have the following connections and interfaces:

    • PM?IF interface to connect the Power Module to the Control Unit. The Power Module also supplies power to the Control Unit using an integrated power supply
    • Motor connection using screw-type terminals or screw studs
    • 2 PE/protective conductor connections
    • Shield connection plate

    Connection example for PM240?2 Power Modules, frame sizes FSA to FSC, with or without integrated line filter

    Connection example for PM240?2 Power Modules, frame sizes FSD to FSG, with or without integrated line filter

    Connection example for PM250 Power Modules with or without integrated line filter

    Power and DC b components that are optionally available depending on the Power Module used

    The following line-side components, DC b components and load-side power components are optionally available in the appropriate frames sizes for the Power Modules:

    Frame size

    FSA

    FSB

    FSC

    FSD

    FSE

    FSF

    FSG

    PM240?2 Power Module with integrated braking chopper

    Available frame sizes

    • 200 V versions

    ? 1)

    ? 1)

    ? 1)

    • 400 V versions

    • 690 V versions

    ? 2)

    ? 2)

    Line-side components

    Line filter class A

    F

    F

    F

    F 1)

    F 1)

    F 1)

    Line filter class B (only for 400 V versions)

    U 3)

    U 3)

    U 3)

    Line filters Category C2 or C3 (for 400 V versions frame size FSG)

    I

    Line filters Category C3 (for 690 V versions frame size FSG)

    I 4)

    Line reactor (only for 3 AC versions 5))

    S 6)

    S 6)

    S 6)

    I

    I

    I

    I

    DC b components

    Braking resistor

    Load-side power components

    Output reactor

    S 2)

    S 2)

    dv/dt filter plus VPL (for 400 V and 690 V versions only 9))

    PM250 Power Module with line-commutated energy recovery

在線詢盤/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。我們?cè)瓌t 上建議您選擇本網(wǎng)高級(jí)會(huì)員或VIP會(huì)員。
    企業(yè)信息
    上海斌勤電氣技術(shù)有限公司
    會(huì)員級(jí)別:試用會(huì)員
    ------------ 聯(lián)系方式 ------------
    聯(lián)系人:康奎(先生)
    聯(lián)系電話:1862-1061383
    聯(lián)系手機(jī):18621061383
    傳真號(hào)碼:1862-1061383
    企業(yè)郵箱:192061030@qq.com
    網(wǎng)址:
    郵編:201501
    推薦供應(yīng)
    0571-87774297