武漢盛美特機(jī)電設(shè)備有限公司主營:REXROTH德國力士樂、VICKERS美國威格士、ATOS意大利阿托斯、SUN美國太陽、DENISON法國丹尼遜、PARKER美國派克、DUPLOMATIC意大利迪普馬、HAWE德國哈威、HYDAC賀德克,CALZONI意大利卡桑尼、MOOG美國穆格,HYDRAFORCE海德福斯,雅歌輝托斯等,價(jià)格優(yōu)勢,歡迎詢價(jià)。
武漢盛美特機(jī)電設(shè)備有限公司
聯(lián)系人:白建新
Q Q: 2480594461
手機(jī): 18717137600
電話:027-65384569
地址:武漢市武昌區(qū)白沙洲觀瀾天地三棟809室
D41FHB11F1VE0048
D41FHE02C1NE0048
D81FSE01E5NLW039
D111FSE01L5NLW037
D1FPE55MA9NB0015
D36FHE52A1NB0048
D41FHE01C4NS0048
D41FHE01F1NS0048
D41FSE01C5NLW039
D81FSE06E4NXW039
D31FHB31C4NS0047
D81FHE52E2NB0048
D31FHA31A2NB0047
D3FPB32YC9NB0316
D41FHA63E2NB0048
D81FHB14H1NB0048
D31FSE01B2NLW037
D41FHE52C4NS0048
D41FHE52F1NS0048
D41FHE82C1NE0048
D91FWE01HC1NXW028
D91FWB32HC5NLW028Electrical characteristics (D1FV OBE)
Duty ratio [%] 100 ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (plugged and mounted)
Supply voltage/ripple DC [V] 18...30, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0
Pre fusing medium lag [A] 2.5
Input signal
Codes F0 & W5
voltage [V] +10...0...-10, ripple < 0.01 % eff., surge free, Ri = 100 kOhm, 0...+10 V T P -> A
Codes M0
voltage [V] +10...0...-10, ripple < 0.01 % eff., surge free, Ri = 100 kOhm, 0...+10 V T P -> B
Codes S0 & W5
current
[mA] 4...12...20, ripple < 0.01 % eff., surge free, Ri = <250 Ohm, 12...20 mA T P -> A
< 3.6 mA = enable off,
> 3.8 mA = enable on (acc. to NAMUR NE43)
Code G0 [mA] +20...0...-20, ripple < 0.01 % eff., surge free, Ri = <250 Ohm, 0...+20 mA T P -> A
Differential b max.
Codes F0, G0, M0 & S0 [V]
30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Code W5 [V]
30 for terminal 4 and 5 against PE (terminal PE)
11 for terminal 4 and 5 against 0V (terminal 2)
Channel recall signal [V] 0...2.5: off / 5...30: on / Ri = 100 kOhm
Min [%] 0...50
Adjustment ranges Max [%] 50...100
Ramp [s] 0...32.5
Interface RS 232, betrizing connection 5pole
EMC EN 61000-6-2, EN 61000-6-4
Central connection
Codes F0, G0, M0 & S0
Code W5
6 + PE acc. to EN 175201-804
11 + PE acc. to EN 175201-804
Wiring min.
Codes F0, G0, M0 & S0
Code W5
[mm2]
[mm2]
7 x 1.0 (AWG16) overall braid shield
11 x 1.0 (AWG16) overall braid shieldFPM
D1FV UK.indd RH 14.10.2015
3-52
Proportional Pressure Reducing Valve
Series D1FV
3
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Technical Data
General
Design Direct operated proportional pressure reducing valve
Actuation Proportional solenoid
Size NG06/CETOP 03/NFPA D03
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting b unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight (OBE) [kg] 2.2 (2.9)
Vibration resistance [g]
10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350; Port T 185
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524...535, other on request
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity permitted [cSt] /
recommended [cSt] /
[mm2/s]
[mm2/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Max. flow [l/min] 10
Min. primary pressure [bar] 30 at 25 pressure range, 50 at 45 pressure range
Static / Dynamic
Hysteresis [%] <4
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics (D1FV)
Duty ratio [%] 100 ED; CAUTION: coil temperature up to 150 °C possible
Protection class
Standard (as per EN175301-803) IP65 in accordance with EN60529 (with correctly mounted
plug-in connector); DT04-2P “Deutsch“ IP69K (with correctly mounted plug-in connector)
Supply voltage [V] 12
Current consumption [A] 2.2
Resistance [Ohm] 4.4
Solenoid connection
Connector as per EN 175301-803 (code W), DT04-2P “Deutsch“ connector (code J).
Solenoid identification as per ISO 9461.
Wiring min. [mm2] 3x1.5 (AWG 16) overall braid shield (code W), "Deutsch" connector DP4 2 Pin (code J)
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
1) If valves with onboard electronics are used in safety-related parts of control systems,