S120控制單元6SL3040-0JA00-0AA0
S120控制單元6SL3040-0JA00-0AA0
產(chǎn)品價格:¥電議
上架日期:2018-09-18 13:14:00
產(chǎn)地:德國
發(fā)貨地:上海
供應(yīng)數(shù)量:不限
最少起訂:1件
瀏覽量:876
資料下載:暫無資料下載
其他下載:暫無相關(guān)下載
詳細(xì)說明

    S120控制單元6SL3040-0JA00-0AA0 


    上海斌勤電氣技術(shù)有限公司專業(yè)從事西門子這個品牌已經(jīng)有10年。
    在松江工業(yè)園區(qū)有一定的名聲   
    不要問我有沒有  西門子常規(guī)的都現(xiàn)貨  支持上門提貨

    有需要的新老顧客歡迎上門提貨談生意(老顧客注意公司地址更改)
    上海斌勤電氣技術(shù)有限公司(西門子合作伙伴)
    聯(lián)系人 :康 奎(業(yè)務(wù)經(jīng)理)發(fā)布(聯(lián)系我有優(yōu)惠福利哦)
    地   址:上海市松江區(qū)三新北路1800弄(松江商務(wù)電子園區(qū))24號樓5005室.

    CU305 Control Unit

    跳轉(zhuǎn)到

    概述

    CU305 PN Control Unit

    The CU305 Control Unit for the communication and open-loop/closed-loop control functions of a SINAMICS S110 is combined with the PM240?2 Power Module in blocksize bat (usable as of firmware V4.4 SP3) to create a powerful single drive.

    設(shè)計

    The CU305 Control Unit features the following connections and interfaces as standard:

    • Fieldbus interface
      • CU305 PN: 1 PROFINET interface with 2 ports (RJ45 sockets) with PROFIdrive V4 profile
      • CU305 DP: 1 PROFIBUS interface with PROFIdrive V4 profile
    • 1 DRIVE-CLiQ socket, used solely to connect a DRIVE-CLiQ motor or a Sensor Module
    • 1 onboard encoder buation for buating the following encoder signals
      • Incremental encoder TTL/HTL
      • SSI encoder without incremental signals
    • 1 PE/protective conductor connection
    • 1 connection for the electronics power supply via the 24 V DC power supply connector
    • 1 temperature sensor b (KTY84?130 or PTC)
    • 3 beterizable, fail-safe digital bs (isolated), or alternatively 6 beterizable digital bs (isolated)
    • 5 beterizable digital bs (isolated)
    • 1 beterizable, fail-safe digital output (isolated), or alternatively 1 digital output (isolated)
    • 4 beterizable bidirectional digital bs/outputs
    • 1 analog b ± 10 V, resolution 12 bit + sign
    • 1 serial RS232 interface
    • 1 slot for the memory card on which the firmware, beters and licenses can be stored
    • 1 PM-IF interface for communication with the PM240?2 Power Modules in blocksize bat (usable as of firmware V4.4 SP3)
    • 2 test sockets and one reference ground for commissioning support
    • 1 interface to the BOP20 Basic Operator Panel

    集成

    The CU305 Control Unit controls the PM240 2 Power Module in blocksize bat (usable as of firmware V4.4 SP3) via the PM-IF interface.

    A BOP20 Basic Operator Panel can also be snapped directly onto the CU305 for diagnostic purposes.

    DRIVE-CLiQ motors can be connected to the integrated DRIVE-CLiQ socket as well as Sensor Modules (SMC) to permit the operation of motors without a DRIVE-CLiQ interface.

    The status of the CU305 is indicated via multi-color LEDs.

    The CU305 can be operated optionally with memory card. The firmware and project data are stored on the memory card pluggable from below, so that the CU305 can be replaced without the support of software tools. This memory card can also be used to perb standard commissioning on multiple drives of identical type. The card is available as an empty memory card or containing the latest drive firmware version. The card also contains the safety license for the Extended Safety Functions. To use these Extended Safety Functions, a memory card containing the safety license must be permanently inserted.

    The CU305 and other connected components are commissioned and diagnosed with the STARTER commissioning tool.

    Connection example of CU305 Control Unit

    技術(shù)規(guī)范

    CU305 PN / CU305 DP Control Units

    PROFINET: 6SL3040-0JA01-0AA0

    PROFIBUS: 6SL3040-0JA00-0AA0

     

    Current requirement

    At 24 V DC, max.
    without taking account of digital outputs and DRIVE-CLiQ supply

    0.8 A for CU305 incl. 350 mA for HTL encoder + 0.5 A for PM240?2 Power Module

    Conductor cross-section, max.

    2.5 mm2

    Fuse protection, max.

    20 A

    Digital bs

    in accordance with IEC 61131?2 Type 1

    3 isolated fail-safe bs

    5 isolated digital bs

    • Voltage

    -3 ... +30 V

    • Low level (an open digital b is interpreted as "low")

    -3 ... +5 V

    • High level

    15 ... 30 V

    • Current consumption at 24 V DC, typ.

    6 mA

    • Delay time of digital bs 1), approx.

     

    • L → H

    15 μs

    • H → L

    55 μs

    • Delay time of high-speed digital bs 1), approx. 
      (high-speed digital bs can be used for b detection)

     

    • L → H

    5 μs

    • H → L

    5 μs

    • Conductor cross-section, max.

    1.5 mm2

    Digital outputs

    (continuously short-circuit-proof)

    1 fail-safe digital output

    4 bidirectional digital bs/digital outputs, not isolated

    • Voltage

    24 V DC

    • Load current per digital output 2), max.

    100 mA

    • Delay time 1), approx.

    150 μs

    • Conductor cross-section, max.

    1.5 mm2

    Analog b

    -10 ... +10 V
    Resolution 12 bits + sign

    • Internal resistance

    15 kΩ

    Encoder buation

    • Incremental encoder TTL/HTL
    • SSI encoder without incremental signals
    • Encoder supply

    24 V DC/0.35 A or 5 V DC/0.35 A

    • Input current range TTL/HTL

    2 ... 10 mA (typ. 5 mA)

    • Encoder frequency, max.

    500 kHz

    • SSI baud rate

    100 ... 250 kBaud
    depending on cable length

    • Resolution absolute b SSI

    30 bit

    • Cable length, max.

     

    • TTL encoder

    100 m (328 ft)

    (only bipolar signals permitted) 3)

    • HTL encoder

    100 m (328 ft) for unipolar signals

    300 m (984 ft) for bipolar signals 3)

    • SSI encoder

    100 m (328 ft)

    Power loss

    <20 W

    PE connection

    M5 screw

    Dimensions

     

    • Width

    73 mm (2.87 in)

    • Height

     

    • CU305 PN

    195 mm (7.68 in)

    • CU305 DP

    183.2 mm (7.21 in)

    • Depth

     

    • CU305 PN

    71 mm (2.80 in)

    • CU305 DP

    55 mm (2.17 in)

    Weight, approx.

    0.95 kg (2.09 lb)

    Certificate of suitability

    cULus


    1)The specified delay times refer to the hardware. The actual reb time depends on the time slice in which the digital b or output is processed.

    2) In order to use the digital outputs, an external 24 V power supply must be connected to terminal X124.

    3) Signal cables twisted in pairs and shielded.



    S120控制單元6SL3040-0JA00-0AA0 

在線詢盤/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對此不承擔(dān)任何保證責(zé)任。我們原則 上建議您選擇本網(wǎng)高級會員或VIP會員。
    企業(yè)信息
    上海斌勤電氣技術(shù)有限公司
    會員級別:試用會員
    ------------ 聯(lián)系方式 ------------
    聯(lián)系人:康奎(先生)
    聯(lián)系電話:1862-1061383
    聯(lián)系手機(jī):18621061383
    傳真號碼:1862-1061383
    企業(yè)郵箱:192061030@qq.com
    網(wǎng)址:
    郵編:201501
    推薦供應(yīng)
    0571-87774297